Drill down into a category below to find more filters
Search Within
[-] Shop By
In Stock Only (6)
[-] Brand/Series
KFD Series (14)
[-] Input Type
Analog (3)
Analogue (2)
Current (2)
Current, Voltage (2)
Digital (2)
Frequency (1)
Potentiometer (1)
Voltage (1)
[-] Input, Range
0 to 10, 0 to 20 V, mA (1)
0 to 5, 16 to 30 V, VDC (1)
1 MHz to 12 kHz (1)
-100 to +100, 5, 18 V, mA, mV (1)
4 to 20 mA (2)
[-] Output Type
Current (9)
Current, Voltage (2)
Relay (1)
Transistor (1)
Voltage (1)
[-] Interface
RS232 (2)
RS485 (1)
[+] Number of Channels
1 (9)
2 (4)
4 (1)
[+] Mounting Type
DIN Rail (13)
[+] Supply Voltage
12 to 35 VDC (2)
20 to 30 (1)
20 to 30 VDC (3)
20 to 35 (2)
20 to 35 VDC (3)
24VDC (2)
5 to 35 VDC (1)
[+] Temperature, Operating, Range
-20 to +60 °C (9)
[+] Special Features
1-Channel Isolated Barrier, Terminal Blocks with Test Sockets (1)
2-Channel Isolated Barrier, Relay Contact Output (1)
DIP Switch Selectable Ranges, Sensor Breakage Detection (1)
High Field Voltage 17.6 V DC, Terminals with Test Points (1)
Lead Resistance Compensation Adjustment (1)
Line Fault (LFD) & Sensor Burnout Detection (1)
Line Fault Detection (LFD) (4)
Line Fault Detection (LFD), Potentiometer or DIP Switch Selectable Ranges (1)
Reverse Polarity Protection (1)
Terminal Blocks with Test Sockets (1)
Terminals with Test Points, 1-Channel Signal Conditioner (1)
[+] Standards
116-0129, 116-0173 (cULus), BAS 98 ATEX 7343TÜV 99 ATEX 1499 X, CE, FM Approval, IEC 61508, IECEx Approval, IECEx BAS 05.0004, UL Approval (1)
116-0302 (cFMus), FM Approval, IECEx Approval, IECEx TUN 06.0005, [Ex ia Ga] IIC, [Ex iaD], [Ex ia] I (1)
ATEX, CE, EN 50014, EN 50020, EN 60079-0 :2006, EN 60079-15: 2005 (1)
ATEX, CE, EN 61326-1: 2006, EX, IEC 60529: 2001, NE 21: 2006, UL 61010-1: 2004 (1)
CE, E223772 UL (NRAQ), E223772 cUL (NRAQ7), IEC 61508, IEC 61511, PF 08 CERT 1216 X (1)
CE, EN 61010-1:2010, IEC 60529:2001, IEC 61508, NE 21:2011 (2)
CE, EN 61326-1:2006, IEC 60529:2001, NE 21:2006 (1)
CE, IEC⁄EN 60079-11, TÜV 01 ATEX 1777X, ZELM 00 ATEX 0036 (1)
[+] Temperature, Operating, Minimum
-20 °C (9)
[+] Temperature, Operating, Maximum
60 °C (9)
[-] Manufacturer
Pepperl+Fuchs Process Automation (14)

14 results found for "frequency input signal conditioner"
Sort By: 
Best Match
Show
20
Per Page
 Page of 1 
Extended Attributes
 
 
 
 
 
Info Availability Price (USD) Quantity Brand/Series Input Type Input, Range Output Type Interface Number of Channels Mounting Type Supply Voltage Temperature, Operating, Range Special Features Standards Temperature, Operating, Minimum Temperature, Operating, Maximum
 
 
 
 
 
                                 
You only can compare up to 5 products at a time.
In Stock: 5
+1    $540.21
+3    $513.20
Each


Current 4 to 20 mA Current 2 DIN Rail 5 to 35 VDC -20 to +60 °C Reverse Polarity Protection 116-0129, 116-0173 (cULus), BAS 98 ATEX 7343TÜV 99 ATEX 1499 X, CE, FM Approval, IEC 61508, IECEx Approval, IECEx BAS 05.0004, UL Approval -20 °C 60 °C
You only can compare up to 5 products at a time.
In Stock: 14
+1    $493.70
+3    $469.02
Each


Analog Current 1 DIN Rail 24VDC 1-Channel Isolated Barrier, Terminal Blocks with Test Sockets
You only can compare up to 5 products at a time.
In Stock: 19
+1    $434.26
+3    $412.55
Each


Digital Relay 2 DIN Rail 24VDC 2-Channel Isolated Barrier, Relay Contact Output
You only can compare up to 5 products at a time.
In Stock: 3
+1    $447.17
+3    $424.81
Each


Digital Transistor 2 DIN Rail 20 to 30 Line Fault Detection (LFD)
You only can compare up to 5 products at a time.
In Stock: 5
+1    $736.67
+3    $699.84
Each


Potentiometer Current 1 DIN Rail 20 to 35 VDC -20 to +60 °C Lead Resistance Compensation Adjustment ATEX, CE, EN 61326-1: 2006, EX, IEC 60529: 2001, NE 21: 2006, UL 61010-1: 2004 -20 °C 60 °C
You only can compare up to 5 products at a time.
In Stock: 7
+1    $578.96
+3    $550.01
Each


Current, Voltage 0 to 10, 0 to 20 V, mA Current 1 12 to 35 VDC -20 to +60 °C Line Fault Detection (LFD), Potentiometer or DIP Switch Selectable Ranges ATEX, CE, EN 50014, EN 50020, EN 60079-0 :2006, EN 60079-15: 2005 -20 °C 60 °C
You only can compare up to 5 products at a time.
In Stock: 0
+1    $297.24
+3    $282.38
Each


Analog Current 1 DIN Rail 20 to 35 Terminals with Test Points, 1-Channel Signal Conditioner
You only can compare up to 5 products at a time.
In Stock: 0
+1    $557.00
+3    $529.15
Each


Frequency 1 MHz to 12 kHz Current RS232 1 DIN Rail 20 to 30 VDC -20 to +60 °C Line Fault Detection (LFD) CE, E223772 UL (NRAQ), E223772 cUL (NRAQ7), IEC 61508, IEC 61511, PF 08 CERT 1216 X -20 °C 60 °C
You only can compare up to 5 products at a time.
In Stock: 0
+1    $482.04
+3    $457.94
Each


Analogue Current 1 DIN Rail 12 to 35 VDC -20 to +60 °C DIP Switch Selectable Ranges, Sensor Breakage Detection CE, IEC⁄EN 60079-11, TÜV 01 ATEX 1777X, ZELM 00 ATEX 0036 -20 °C 60 °C
You only can compare up to 5 products at a time.
In Stock: 0
+1    $1,417.70
+3    $1,346.82
Each


Current, Voltage -100 to +100, 5, 18 V, mA, mV Current, Voltage RS485 1 DIN Rail 20 to 35 VDC -20 to +60 °C Line Fault Detection (LFD) 116-0302 (cFMus), FM Approval, IECEx Approval, IECEx TUN 06.0005, [Ex ia Ga] IIC, [Ex iaD], [Ex ia] I -20 °C 60 °C
You only can compare up to 5 products at a time.
In Stock: 0
+1    $557.00
+3    $529.15
Each


Current 4 to 20 mA Current 2 DIN Rail 20 to 35 VDC -20 to +60 °C Terminal Blocks with Test Sockets CE, EN 61010-1:2010, IEC 60529:2001, IEC 61508, NE 21:2011 -20 °C 60 °C
You only can compare up to 5 products at a time.
In Stock: 0
+1    $469.12
+3    $445.66
Each


Analogue Current RS232 1 DIN Rail 20 to 30 VDC -20 to +60 °C Line Fault (LFD) & Sensor Burnout Detection CE, EN 61326-1:2006, IEC 60529:2001, NE 21:2006 -20 °C 60 °C
You only can compare up to 5 products at a time.
In Stock: 0
+1    $275.28
+3    $261.52
Each


Voltage 0 to 5, 16 to 30 V, VDC Current, Voltage 4 DIN Rail 20 to 30 VDC -20 to +60 °C Line Fault Detection (LFD) CE, EN 61010-1:2010, IEC 60529:2001, IEC 61508, NE 21:2011 -20 °C 60 °C
You only can compare up to 5 products at a time.
In Stock: 0
+1    $493.70
+3    $469.02
Each


Analog Voltage 1 DIN Rail 20 to 35 High Field Voltage 17.6 V DC, Terminals with Test Points
 Page of 1